ČSN EN 62220-1-1 (364730)

Medical electrical equipment - Characteristics of digital x-ray imaging devices - Part 1-1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging

Automatische name übersetzung:

Medizinische elektrische Geräte - Merkmale digitaler Röntgenbildgeräte- Teil 1-1: Bestimmung der Detektiv Quanteneffizienz - Detektoren in Röntgenaufnahmen ( Standard zur unmittelbaren Verwendung als CSN) verwendet.



NORM herausgegeben am 1.12.2015


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis17.30 ohne MWS
17.30

Informationen über die Norm:

Bezeichnung normen: ČSN EN 62220-1-1
Zeichen: 364730
Katalog-Nummer: 98105
Ausgabedatum normen: 1.12.2015
SKU: NS-621645
Zahl der Seiten: 48
Gewicht ca.: 144 g (0.32 Pfund)
Land: Tschechische technische Norm
Kategorie: Technische Normen ČSN

Kategorie - ähnliche Normen:

Radiographic equipment

Die Annotation des Normtextes ČSN EN 62220-1-1 (364730):

This part of IEC 62220 specifies the method for the determination of the DETECTIVE QUANTUM EFFICIENCY (DQE) of DIGITAL X-RAY IMAGING DEVICES as a function of AIR KERMA and of SPATIAL FREQUENCY for the working conditions in the range of the medical application as specified by the MANUFACTURER. The intended users of this part of IEC 62220 are manufacturers and well equipped test laboratories. NOTE 1: While not recommended, applying this standard to determine the DQE of digital X-ray imaging devices integrated in a clinical system is not excluded as long as the requirements as set in this standard are respected. Points of additional attention could be (for example but not exclusively) the establishment of the required RADIATION QUALITIES, minimizing influences of scattered and back-scattered radiation, accurate AIR KERMA measurements, positioning of the TEST DEVICE, presence of protective covers, removal of ANTI-SCATTER GRID. This Part 1-1 is restricted to DIGITAL X-RAY IMAGING DEVICES that are used for radiographic imaging such as, but not exclusively, CR systems, direct and indirect flat panel-detector based systems. It is not recommended to use this part of IEC 62220 for digital X-RAY IMAGE INTENSIFIER-based systems. NOTE 2: The use of this standard for X-RAY IMAGE INTENSIFER-based systems is discouraged based on the low frequency drop, vignetting and geometrical distortion present in these devices which may put severe limitations on the applicability of the measurement methods described in this standard. This part of IEC 62220 is not applicable to: DIGITAL X-RAY IMAGING DEVICES intended to be used in mammography or in dental radiography; slot scanning DIGITAL X-RAY IMAGING DEVICES; COMPUTED TOMOGRAPHY; devices for dynamic imaging (where series of images are acquired, as in fluoroscopy or cardiac imaging). NOTE 3: The devices noted above are excluded because they contain many parameters (for instance, beam qualities, geometry, time dependence, etc.) which differ from those important for RADIOGRAPHY. Some of these techniques are treated in other parts of the IEC 62220 standards (IEC 62220-1-2 and IEC 62220-1-3)

Empfehlungen:

Aktualisierung der technischen Normen

Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.

Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.