ČSN EN IEC 61223-3-6 (854012)

Evaluation and routine testing in medical imaging departments - Part 3-6: Acceptance and constancy tests - Imaging performance of mammographic X-ray equipment used in a mammographic tomosynthesis mode of operation

Name übersetzen

NORM herausgegeben am 1.9.2020


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis22.70 ohne MWS
22.70

Informationen über die Norm:

Bezeichnung normen: ČSN EN IEC 61223-3-6
Zeichen: 854012
Katalog-Nummer: 510297
Ausgabedatum normen: 1.9.2020
SKU: NS-1003329
Zahl der Seiten: 64
Gewicht ca.: 192 g (0.42 Pfund)
Land: Tschechische technische Norm
Kategorie: Technische Normen ČSN

Kategorie - ähnliche Normen:

Radiographic equipment

Die Annotation des Normtextes ČSN EN IEC 61223-3-6 (854012):

This part of IEC 61223 applies to the performance of MAMMOGRAPHIC X-RAY EQUIPMENT when used in MAMMOGRAPHIC TOMOSYNTHESIS modes of operation, with respect to image quality and dose. Excluded from the scope of this document are: - MAMMOGRAPHIC X-RAY EQUIPMENT modes of operation other than MAMMOGRAPHIC TOMOSYNTHESIS; - 2D images synthesised from the tomosynthesis images; - reconstructive TOMOGRAPHY other than MAMMOGRAPHIC TOMOSYNTHESIS; - CT SCANNERS covered by IEC 61223-3-5. This document defines: a) the essential parameters which describe the acceptability criteria of MAMMOGRAPHIC TOMOSYNTHESIS modes of operation of MAMMOGRAPHIC X-RAY EQUIPMENT with regard to image quality and dose, b) the methods of testing whether measured quantities related to those parameters comply with specified tolerances, and c) CONSTANCY TEST frequency when required. This document is intended to be applied along with the acceptability criteria included in IEC 61223-3-2 or equivalent protocol for 2D mammography which are also relevant for MAMMOGRAPHIC TOMOSYNTHESIS modes of operation. These methods mainly rely on non-invasive measurements that use appropriate test equipment and are performed during or after the installation. Signed statements covering steps in the installation procedure can be used as part of the ACCEPTANCE TEST. Tests required by a higher level of compliance take precedence over similar tests with a lower level of compliance. When the results of the ACCEPTANCE TEST are in compliance with the expected values, the BASELINE VALUES for the subsequent CONSTANCY TESTS are establishe

Empfehlungen:

Aktualisierung der technischen Normen

Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.

Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.