ČSN EN ISO 14146 (404315)

Radiological protection - Criteria and performance limits for the periodic evaluation of dosimetry services

Name übersetzen

NORM herausgegeben am 1.9.2021


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis13.50 ohne MWS
13.50

Informationen über die Norm:

Bezeichnung normen: ČSN EN ISO 14146
Zeichen: 404315
Katalog-Nummer: 512580
Ausgabedatum normen: 1.9.2021
SKU: NS-1034819
Zahl der Seiten: 24
Gewicht ca.: 72 g (0.16 Pfund)
Land: Tschechische technische Norm
Kategorie: Technische Normen ČSN

Kategorie - ähnliche Normen:

Radiation protection

Die Annotation des Normtextes ČSN EN ISO 14146 (404315):

quality of a supplier of a dosimetry service depends on both the characteristics of the approved (type-tested) dosimetry system and the training and experience of the staff, together with the calibration procedures and quality assurance programmes. This document specifies the criteria and the test procedures to be used for the periodic verification of the performance of dosimetry services supplying personal and/or area dosemeters. An area dosemeter can be a workplace dosemeter or an environmental dosemeter. The performance evaluation can be carried out as a part of the approval procedure for a dosimetry system or as an independent check to verify that a dosimetry service fulfils specified national or international type test performance requirements under representative exposure conditions that are expected or mimic workplace fields from the radiological activities being monitored. This document applies to personal and area dosemeters for the assessment of external photon radiation with a (fluence weighted) mean energy between 8 keV and 10 MeV, beta radiation with a (fluence weighted) mean energy between 60 keV and 1,2 MeV, and neutron radiation with a (fluence weighted) mean energy between 25,3 meV (i.e. thermal neutrons with a Maxwellian energy distribution with kT = 25,3 meV) and 200 MeV. It covers all types of personal and area dosemeters needing laboratory processing (e.g. thermoluminescent, optically stimulated luminescence, radiophotoluminescent, track detectors or photographic-film dosemeters) and involving continuous measurements or measurements repeated regularly at fixed time intervals (e.g. several weeks, one month). Active dosemeters (for dose measurement) may also be treated according to this document. Then, they should be treated as if they were passive (i.e. the dosimetry service reads their indicated values and reports them to the evaluation organization)

Empfehlungen:

Aktualisierung der Gesetze

Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.