ČSN EN ISO 80601-2-87 (364801)

Medical electrical equipment - Part 2-87: Particular requirements for basic safety and essential performance of high-frequency ventilators

Name übersetzen

NORM herausgegeben am 1.11.2021


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis46.30 ohne MWS
46.30

Informationen über die Norm:

Bezeichnung normen: ČSN EN ISO 80601-2-87
Zeichen: 364801
Katalog-Nummer: 512946
Ausgabedatum normen: 1.11.2021
SKU: NS-1041192
Zahl der Seiten: 150
Gewicht ca.: 481 g (1.06 Pfund)
Land: Tschechische technische Norm
Kategorie: Technische Normen ČSN

Die Annotation des Normtextes ČSN EN ISO 80601-2-87 (364801):

Clause 1 of IEC 60601-1:2005+AMD1:2012+AMD2:2020 applies, except as follows: NOTE - The general standard is IEC 60601-1:2005+AMD1:2012+AMD2:2020. Replacement: This document applies to the basic safety and essential performance of a high-frequency ventilator (HFV) in combination with its accessories, hereafter referred to as ME equipment: - intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility; NOTE 1 - For the purposes of this document, such an environment is referred to as a critical care environment. High-frequency ventilators for this environment are considered life-sustaining. NOTE 2 - For the purposes of this document, such a high-frequency ventilator can provide transport within a professional healthcare facility (i.e., be a transit-operable ventilator). NOTE 3 - A high-frequency ventilator intended for use in transport within a professional healthcare facility is not considered as a ventilator intended for the emergency medical services environment. - intended to be operated by a healthcare professional operator; - intended for those patients who need differing levels of support from artificial ventilation including ventilator-dependent patients; and - capable of providing more than 150 inflations/min. There are three principal designations of HFV: - high-frequency percussive ventilation [HFPV, with a typical HFV frequency of (60 to 1 000) HFV inflations/min]; - high-frequency jet ventilation [HFJV, with a typical HFV frequency of (100 to 1 500) HFV inflations/min]; and - high-frequency oscillatory ventilation [HFOV, with a typical HFV frequency of (180 to 1200) HFV inflations/min and typically having an active expiratory phase]. Additionally, HFV designations can be combined together or with ventilation at rates less than 150 inflations/min. * A high-frequency ventilator is not considered a physiologic closed loop-control system unless it uses a physiological patient variable to adjust the ventilation therapy settings. This document is also applicable to those accessories intended by their manufacturer to be connected to an HFV breathing system, or to a high-frequency ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the high-frequency ventilator. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of IEC 60601-1:2005. NOTE 4 - Additional information can be found in 4.2 of IEC 60601-1:2005+AMD1:2012. This document is not applicable to ME equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility. This document does not specify the requirements for: - non-high-frequency ventilators or accessories which provide conventional ventilation for use in critical care environments, which are given in ISO 80601-2-12 [23];. NOTE 5 - An HFV can incorporate conventional critical care ventilator operational modes, in which case ISO 80601-2-12 is applicable to those modes. - ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601-2-13 [24]; - ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601-2-84, the replacement for ISO 10651-3 [13]; NOTE 6 - An HFV can incorporate EMS ventilator capability. - ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601-2-72 [26]; - ventilators or accessories intended for home-care ventilatory support devices, which are given in ISO 80601-2-79 [27] and ISO 80601-2-80 [28], the replacements for ISO 10651-6 [15]; - sleep apnoea breathing therapy ME equipment, which are given in ISO 80601-2-70 [25]; - bi-level positive airway pressure (bi-level PAP) ME equipment; - continuous positive airway pressure (CPAP) ME equipment; - respiratory high-flow ME equipment, which are given in ISO 80601-2-90:-1; and - cuirass or "iron-lung" ventilation equipment. This document is a particular standard in the IEC 60601 series, the IEC 80601 series and the ISO 80601 series

Empfehlungen:

Aktualisierung der Gesetze

Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Vorschriften verwenden?
Wir bieten Ihnen Lösungen, damit Sie immer nur die gültigen (aktuellen) legislativen Vorschriften verwenden könnten.
Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.