Die Norm IEC 62541-9-ed.4.0-RLV 16.4.2026 Ansicht

IEC 62541-9-ed.4.0-RLV

OPC unified architecture - Part 9: Alarms and Conditions

Name übersetzen

NORM herausgegeben am 16.4.2026


Sprache
Realisierung
ZugänglichkeitAUF LAGER
Preis1059.30 ohne MWS
1 059.30

Informationen über die Norm:

Bezeichnung normen: IEC 62541-9-ed.4.0-RLV
Ausgabedatum normen: 16.4.2026
SKU: NS-1268828
Zahl der Seiten: 337
Gewicht ca.: 1042 g (2.30 Pfund)
Land: Internationale technische Norm
Kategorie: Technische Normen IEC

Die Annotation des Normtextes IEC 62541-9-ed.4.0-RLV :

IEC 62541-9:2026 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 62541-9:2026 specifies the representation of Alarms and Conditions in the OPC Unified Architecture. Included is the Information Model representation of Alarms and Conditions in the OPC UA address space. Other aspects of alarm systems like alarm philosophy, life cycle, alarm response times, alarm types and many other details are captured in standards such as IEC 62682 and ISA 18.2. The Alarms and Conditions Information Model in this document, is designed in accordance with IEC 62682 and ISA 18.2. Annex C specifies a recommended mapping between OPC Classic Alarm & Events (A&E) servers to the model described in this document. Annex A describes recommended localized names for Alarm states. Annex B describes examples (e.g. Event sequences, Alarm areas in AddressSpace). This fourth edition cancels and replaces the third edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of "Comment" parameter to Alarm shelving methods; b) addition of method that allows a client to get the members of a group, since it is possible that the AddressSpace does not expose instances of alarms; c) addition of deadband properties for all limits in the limit AlarmType (from which all other types described in this issue are derived); d) addition of text explaining the disabling of alarms is no longer supported in ISA 18.2 and that it is maintained in this document for backward compatibility, but that it is recommended that Alarm not be disabled; e) addition of optional severities for limit alarms; f) addition of new AlarmState variable type that can be used to collect alarm information for displays on graphics; g) addition of SupportsFilterRetain property to improve Client filtering; h) removal of ConditionSubClassId and ConditionSubClassNames from the conditiontype definition since they are now defined in BaseEventType.

Empfehlungen:

Aktualisierung der technischen Normen

Wollen Sie sich sicher sein, dass Sie nur die gültigen technischen Normen verwenden?
Wir bieten Ihnen eine Lösung, die Ihnen eine Monatsübersicht über die Aktualität der von Ihnen angewandten Normen sicher stellt.

Brauchen Sie mehr Informationen? Sehen Sie sich diese Seite an.




Cookies Cookies

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können. Klicken Sie auf "OK", um Ihre Zustimmung zu erteilen.

Sie können die Zustimmung verweigern hier.

Hier können Sie Ihre Cookie-Einstellungen nach Ihren Wünschen anpassen.

Wir benötigen Ihre Einwilligung zur Verwendung der einzelnen Daten, damit Sie unter anderem Informationen zu Ihren Interessen einsehen können.